# Bilateral Stimulation Simulator
Simple browser-based tool with an Admin panel and a full-screen Patient view. The Admin controls everything; the Patient view mirrors motion and audio.
## Admin Options
- Shape
- Options: Circle, Square, Triangle
- Shape Color
- Picker + presets: Green, Blue, Yellow, Red, White
- Background Color
- Picker + presets: Green, Blue, Yellow, Red, White
- Direction
- Left↔Right, Up↕Down, Diagonal ↘, Diagonal ↗
- Speed
- Range: 50600 px/s
- Speed Boost: 1×, 2×, 3×, 4× multiplier
- Size
- Range: 10100 px
- Vertical Position
- Range: 0100% (Reset to 50%)
- Glow Pulse
- Enable/Disable
- Glow Radius: 0200%
- Glow Rate: 0.13.0 Hz
- Ramp Speed
- Enable/Disable, Seconds: 160
- When disabled, motion uses constant speed (Linear)
- Smoothness / Easing
- Linear (constant speed)
- Ease In-Out (slows at edges)
- Edge Pause
- Range: 0150 ms
- Wiggle
- Enable/Disable, Amplitude: 010 px
### Audio
- Audio Mode
- Programmatic, From Files, Off
- Programmatic Presets
- Pink Noise, Hybrid (noise + edge cues), Click, Ping, Woodblock
- Bell, Bass, Kick, Snare, Hi-Hat, Sweep, Zap, Bubble
- Pan Sync to Movement
- Toggle on/off
- Pan Rate (for continuous panning)
- Range: 0.12.0 Hz
- Cue Rate (Hybrid)
- Range: 0.13.0 Hz
- Volume
- Range: 0100%
- Test Sound
- Plays the selected programmatic preset briefly
### File Audio
- Choose Folder, select track from dropdown (MP3/WAV)
### Presets (Admin)
- Save: Enter name and save current state
- Apply: Select from list and apply
- Delete: Remove a preset
- Import/Export: JSON of all presets
### Patient Management
- Patient Name: Save patient
- Load Patient: Select from list
- Clear Sessions: Reset history for loaded patient
- Delete Patient: Remove patient record
- Session History: Auto-listed with start/end time and duration
### Session Controls (Preview Panel)
- Timer (minutes)
- Start Session / End Session
- Status + Elapsed time
## Patient View
- Full-screen canvas with motion synced to Admin
- Audio unlock: most browsers require a user gesture (e.g., click or key press) before audio can play
## How to Run
- Open `index.html` and use the Admin panel
- Click “Open Patient View” to launch `patient.html` in a separate tab/window
## Network Mode Setup (Two Computers on the Same WiFi/LAN)
### Overview
- Therapist runs a lightweight relay (`server.py`) once on their computer.
- Admin connects to the relay with a Session ID and copies the Patient Join Link.
- Patient opens the link on their computer and performs a quick gesture to unlock audio.
### OneTime Install (WebSocket Relay)
- Windows:
- Press `Windows` key → type `PowerShell``Enter`
- Check Python: `python --version` (or `py --version`)
- Install package: `python -m pip install websockets` (or `py -m pip install websockets`)
- Start relay: `python server.py` (or `py server.py`)
- If prompted by Windows Defender Firewall, click “Allow access”.
- macOS:
- Press `Cmd+Space` → type `Terminal``Enter`
- Check Python: `python3 --version`
- Install package: `python3 -m pip install websockets`
- Start relay: `python3 server.py`
- Linux (Ubuntu/Debian/Fedora etc.):
- Press `Ctrl+Alt+T` to open Terminal
- Check Python: `python3 --version`
- Install package: `python3 -m pip install websockets`
- Start relay: `python3 server.py`
### Find Your Therapist Computers IP Address
- Windows: run `ipconfig` → use the `IPv4 Address` on your active adapter (e.g., `192.168.1.5`).
- macOS: run `ipconfig getifaddr en0` (WiFi) or `ipconfig getifaddr en1` (alternate); or `ifconfig | grep "inet "`.
- Linux: run `hostname -I` and pick the local `192.168.x.x` address; or `ip addr show`.
### Connect Admin (Therapist Computer)
1) Open Admin in a browser: `http://localhost:8000/`
2) In “Network Mode”:
- Server URL: `ws://<THERAPIST_IP>:8787` (e.g., `ws://192.168.1.5:8787`)
- Session ID: any label you like (e.g., `room-1`)
- Click `Connect`
3) Copy the Patient Join Link shown below the connection fields.
### Connect Patient (Second Computer)
1) Open the copied Patient Join Link in a browser
2) Perform a quick gesture (mouse move or key press) to unlock audio (browser policy)
3) The Patient view will mirror Admin changes in real time
### Tips
- If the Patient does not connect, verify both computers are on the same network and can reach `ws://<THERAPIST_IP>:8787`.
- On Windows, allow the relay through the firewall when prompted.
- You can disconnect Network Mode and continue Local Mode at any time.
## Data Storage
- Presets: `localStorage` key `bls_presets`
- Patients: `localStorage` key `bls_patients`
## Notes
- If Audio is enabled and Programmatic mode is selected, the Patient tab may need one user interaction to unlock audio
- Speed Boost multiplies the slider value for effective motion speed
## ⚠️ Disclaimer
This tool is for research, education, and personal experimentation with bilateral stimulation. It is NOT a substitute for professional therapy, diagnosis, or treatment. Use at your own discretion.